LSP3W-BWW1Q
piece
1000pcs
Absolute maximum ratings(Ta=25℃)
Parameter | Symbol | Test Condition | Value | Unit | |
Min. | Max. | ||||
DC Forward Current | IF | --- | --- | 700 | mA |
Peak Pulse Current | Ipeak | Duty=0.1mS,1kHz | --- | 1000 | mA |
Power Dissipation | Pd | --- | --- | 3.0 | W |
LED Junction Temperature | Tj | --- | --- | 120 | ℃ |
Operating Temperature | Topr | --- | -25 | +80 | ℃ |
Storage Temperature | Tstr | --- | -40 | +100 | ℃ |
ESD Sensitivity | --- | HBM | 8000 | --- | V |
Soldering Temperature | --- | --- | 260℃ for 5 Seconds max |
Electrical and optical characteristics (Ta = 25℃)
Parameter | Symbol | Test Condition | Value | Unit | ||
Min. | Typ. | Max. | ||||
Forward Voltage | VF | IF = 700mA | 3.2 | 3.5 | 4.2 | V |
Luminous Flux | Φv | --- | 100 | --- | lm | |
Viewing Angle | 2θ1/2 | --- | 90 | --- | Deg. | |
Color Temperature | CCT | 4000 | --- | --- | K |
Luminous Flux Bins(Ta = 25℃) Unit: lm
Bin | M | N | P | Q |
Min | 80 | 100 | 120 | 140 |
Max | 100 | 120 | 140 | 160 |
CCT Bins(Ta = 25℃) Unit: K
Bin | W0 | W1 | W2 |
Min | --- | 3000 | 3300 |
Max | 3000 | 3300 | 3600 |
Note
1. Flux is measured with an accuracy of ±15%
2. CCT is measured with an accuracy of ± 200K
3. Dominant Wavelength is measured with an accuracy of ± 1.5nm
4. Forward Voltage is measured with an accuracy of ± 0.15V
Absolute maximum ratings(Ta=25℃)
Parameter | Symbol | Test Condition | Value | Unit | |
Min. | Max. | ||||
DC Forward Current | IF | --- | --- | 700 | mA |
Peak Pulse Current | Ipeak | Duty=0.1mS,1kHz | --- | 1000 | mA |
Power Dissipation | Pd | --- | --- | 3.0 | W |
LED Junction Temperature | Tj | --- | --- | 120 | ℃ |
Operating Temperature | Topr | --- | -25 | +80 | ℃ |
Storage Temperature | Tstr | --- | -40 | +100 | ℃ |
ESD Sensitivity | --- | HBM | 8000 | --- | V |
Soldering Temperature | --- | --- | 260℃ for 5 Seconds max |
Electrical and optical characteristics (Ta = 25℃)
Parameter | Symbol | Test Condition | Value | Unit | ||
Min. | Typ. | Max. | ||||
Forward Voltage | VF | IF = 700mA | 3.2 | 3.5 | 4.2 | V |
Luminous Flux | Φv | --- | 100 | --- | lm | |
Viewing Angle | 2θ1/2 | --- | 90 | --- | Deg. | |
Color Temperature | CCT | 4000 | --- | --- | K |
Luminous Flux Bins(Ta = 25℃) Unit: lm
Bin | M | N | P | Q |
Min | 80 | 100 | 120 | 140 |
Max | 100 | 120 | 140 | 160 |
CCT Bins(Ta = 25℃) Unit: K
Bin | W0 | W1 | W2 |
Min | --- | 3000 | 3300 |
Max | 3000 | 3300 | 3600 |
Note
1. Flux is measured with an accuracy of ±15%
2. CCT is measured with an accuracy of ± 200K
3. Dominant Wavelength is measured with an accuracy of ± 1.5nm